380V Intelligent Soft Starter 5.5kW–630kW Built-in Bypass for Pumps IEC 60947-4-2 CE

Views : 264
Update time : 2026-03-17 08:58:42

380V Intelligent Soft Starter 5.5kW630kW Built-in Bypass for Pumps IEC 60947-4-2 CE

Reduce Inrush Current by 70% | Motor Protector Lower Energy Consumption & Less Downtime


Tired of motor burnout, voltage spikes, pipeline water hammer and sudden production shutdowns?


Our 380V intelligent soft starter limits inrush current by up to 70%, extends motor life by 3x, eliminates pipeline shock, and stabilizes your power grid
saving you from costly repairs and downtime.

Intelligent Soft StarterSoft Starter
Up to 70% Less Inrush Current

Direct start: 68 times rated current

Our soft starter: only 1.54 times rated current

Protect motors, belts, pumps, gears and bearings

No more water hammer or pressure surges for pump systems

Smooth start & soft stop for conveyors, fans, compressors


Standard Built-in Bypass (No Extra Cost)

Automatically switches to bypass after full speed

Eliminates thyristor loss 99%+ operating efficiency

50% less heat generation

Longer service life: 100,000+ cycles

Perfect for long-running pumps, fans, compressors


Full Protection = Less Downtime

Overload / Phase loss / 3-phase imbalance

Over/under voltage / Overheat / Short circuit

LCD fault code display: E01, E02clear at a glance

MTTR reduced by up to 70%

No professional electrician needed for troubleshooting


Easy Operation & Fast Installation

Simple keypad: SET/ENTER/RUN/STOP

Real-time LCD monitoring: voltage, current, status

35mm DIN rail & panel mount compatible

Setup in 10 minutes, no complex training


Global Application & Certifications

Voltage: 380V AC ±15%, 50/60Hz

Power: 5.5kW 630kW

CE, IEC 60947-4-2, ISO 9001

Widely used in Asia, Africa, Middle East, Americas

Motor Soft StarterWater Pump Soft Starter
Why Choose Us

Professional manufacturer for industrial motor control

Strict quality test before shipment

Stable performance, low failure rate

Quick delivery & flexible MOQ

Professional after-sales technical support

Trusted by water utilities, cement plants, factories worldwide


Ideal For

Water pumps / Fire pumps / Pressure pumps

Ventilators & exhaust fans

Belt conveyors & screw conveyors

Air compressors & crushers

HVAC systems & elevators


Get Your Free Professional Solution Now!

Tell us:

Motor power (kW)

Application (pump/fan/conveyor etc.)

Voltage & frequency

We will:

Recommend the right model

Calculate your energy savings

Send best price & datasheet in 24 hours

Inquiry now Get priority support & exclusive discount!

Related News
Read More >>
How to Choose the Right Residential Load Center: The Complete Buying Guide How to Choose the Right Residential Load Center: The Complete Buying Guide
Jul .16.2026
This complete guide explains the functions, application scenarios and core selection criteria of TYE LOAD CENTER for solar PV systems. It covers voltage standards, main current rating, circuit quantity, NEMA protection grades and common selection mistakes, helping engineers and installers pick the best load center for grid-tied and off-grid solar projects.
Laos Electricité du Laos (EDL) Delegation Visits Beite Transformer Co., Ltd. for Technical Exchange and Strategic Cooperation,Company News Laos Electricité du Laos (EDL) Delegation Visits Beite Transformer Co., Ltd. for Technical Exchange and Strategic Cooperation,Company News
Jul .14.2026
Senior delegation from Electricité du Laos (EDL) visited Beite Transformer Co., Ltd. for technical exchanges and factory inspections covering 110kV/220kV power transformers, DC charging piles, high and low voltage complete sets of equipment. A letter of intent for three-year strategic cooperation was signed to jointly boost China-Laos power collaboration and Southeast Asian power grid construction.
Inside a Transformer Insulation Material Factory: How Reliable Insulation Components Are Manufactured Inside a Transformer Insulation Material Factory: How Reliable Insulation Components Are Manufactured
May .21.2026
This article takes readers inside a professional transformer insulation material factory in China to explain how durable, standards-compliant insulation components are made. It covers the importance of insulation materials in transformers, lists commonly used parts such as DDP insulation paper, pressboard, and epoxy insulation, introduces automated CNC processing and modern workshop production, and details applications in both oil-immersed and dry-type transformers. The article also highlights OEM and custom manufacturing capabilities, showing the complete production system and quality control behind reliable transformer insulation solutions.
Insulation Coordination for Low-Voltage Switchgear: IEC 61439 Design Requirements Explained Insulation Coordination for Low-Voltage Switchgear: IEC 61439 Design Requirements Explained
May .16.2026
Our low-voltage switchgear assemblies are designed in accordance with IEC 61439 standards, providing reliable power distribution, protection, and control solutions for industrial and commercial applications.

With optimized insulation coordination design, the system ensures stable performance under demanding operating conditions, including high humidity, high temperature, and unstable power environments. The products feature safe clearance and creepage distances, high dielectric strength, and strong resistance to insulation aging and electrical faults.

Widely used in industrial plants, commercial buildings, renewable energy projects, and infrastructure systems, our switchgear solutions offer:

High operational reliability
Stable electrical performance
Flexible customization
Easy maintenance
Compliance with international IEC standards

We also provide OEM and project-based customization services to meet different market and application requirements.